Table 1. Engine Will Not Crank - Continued
Table 1. Engine Will Not Crank - Continued

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  824    825    826    827    828  829  830    831    832    833    834  
img
TM 5-3805-294-23-1
0123
Table 1. Engine Will Not Crank - Continued.
Test or Inspection
Corrective Action
Malfunction
3.
Measure voltage (Volume 3,
WP 0369) between relay K19
terminal A (Volume 5,
WP 0800, Figure 209) and a
known good ground.
4.
Turn key switch to OFF
1.
If between 22 - 28 volts,
position (TM 5-3805-294-10).
proceed to Malfunction 15.
(Volume 5, WP 0794)
2.
If not between 22 - 28 volts,
discontinue this
troubleshooting procedure and
perform procedure for
Alternator Does Not Charge
Batteries. (Volume 2,
WP 0170)
With the aid of an assistant,
1.
If continuity is not present,
15.
Open Circuit
measure resistance (Volume
replace starter protection
Between Relay K19
wiring harness. (Volume 4,
Terminal A and
3, WP 0369) between relay
Starter Terminal B.
K19 terminal A (Volume 5,
WP 0528) Restore machine to
original condition.
WP 0800, Figure 209) and
starter terminal B. (Volume 5,
2.
If continuity is present, replace
WP 0800, Figure 222) Note
starter positive cable. (Volume
reading.
4, WP 0527) Restore machine
to original condition.
1.
Verify the key switch is in the
16.
Voltage Between
OFF position (TM
Relay K34 Socket
5-3805-294-10). (Volume 5,
G01 and Ground
Not Within 2 Volts of
WP 0794)
Battery Terminal
Voltage.
2.
Measure voltage (Volume 3,
WP 0369) between battery
negative and positive
terminals. (Volume 5,
WP 0800, Figure 5) Note
battery terminal voltage.
0123-6