Table 1. Engine Will Not Crank - Continued
Table 1. Engine Will Not Crank - Continued

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  828    829    830    831    832  833  834    835    836    837    838  
img
TM 5-3805-294-23-1
0123
Table 1. Engine Will Not Crank - Continued.
Test or Inspection
Corrective Action
Malfunction
3.
With the aid of an assistant,
measure voltage (Volume 3,
WP 0369) between starter
terminal C (Volume 5,
WP 0800, Figure 222) and a
known good ground while
turning key switch to START
position for 3 seconds.
(Volume 5, WP 0794) Note
reading.
4.
Turn key switch to OFF
1.
If within 2 volts of battery
position (TM 5-3805-294-10).
terminal voltage, proceed to
Malfunction 23.
(Volume 5, WP 0794)
2.
If not within 2 volts of battery
terminal voltage, replace
starter protection harness.
(Volume 4, WP 0528) Restore
machine to original condition.
1.
Verify the key switch is in the
23.
Voltage Between
OFF position (TM
Starter Terminal C
5-3805-294-10). (Volume 5,
and Starter Ground
Terminal Not Within
WP 0794)
2 Volts of Battery
Terminal Voltage.
2.
Measure voltage (Volume 3,
WP 0369) between battery
negative and positive
terminals. (Volume 5,
WP 0800, Figure 5) Note
battery terminal voltage.
3.
With the aid of an assistant,
measure voltage (Volume 3,
WP 0369) between starter
terminal C (Volume 5,
WP 0800, Figure 222) and
starter ground terminal while
turning key switch to START
position for 3 seconds.
(Volume 5, WP 0794) Note
reading.
0123-10