INSTALLATION - Continued
Figure 2. Filter Installation.

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -4 Page Navigation
  429    430    431    432    433  434  435    436    437    438    439  
img
. .
TM 5-3805-294-23-4
0547
FIELD MAINTENANCE
AIR CONDITIONER/HEATER FRESH AIR FILTER REPLACEMENT
INITIAL SETUP:
Materials/Parts
References (cont.)
Rag, Wiping (Volume 5, WP 0797, Table 1, Item
TM 5-3805-295-13&P (Volume 5, WP 0794)
34)
DA FORM 5988-E or DA FORM 2404 (Volume 5,
WP 0794)
Personnel Required
Heavy Equipment Operator 91L (1)
Equipment Condition
Machine safely parked and shut down
(TM 5-3805-294-10). (Volume 5, WP 0794)
References
TM 5-3805-294-24P: Fig. 127 (Volume 5,
WP 0794)
Time to Complete
0.1 Hour(s)
REMOVAL
NOTE
If HYEX is equipped with a Supplemental Armor Set, refer to and use procedure found in TM
5-3805-295-13&P.
1.
Move two tabs (Figure 1, Item 1) inward on filter (Figure 1, Item 2).
1
1
3
2
HYEX00303
Figure 1. Filter Removal.
2.
Remove filter (Figure 1, Item 2) from housing (Figure 1, Item 3).
END OF TASK
0547-1