Figure 19. Rear of Wiring Harness Installation
Figure 20. Front Of Wiring Harness Installation

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -4 Page Navigation
  459    460    461    462    463  464  465    466    467    468    469  
img
TM 5-3805-294-23-4
0551
INSTALLATION - Continued
20.
Install wiring harness connector M10 (Figure 19, Item 15) to air conditioner/heater blower port change servo
motor (Figure 19, Item 16).
21.
Install wiring harness connector B43 (Figure 19, Item 13) to heater core temperature sensor (Figure 19, Item
14).
22.
Install wiring harness connector R17 (Figure 19, Item 11) to blower motor low speed resistor (Figure 19, Item
12).
23.
Install wiring harness connector M11 (Figure 20, Item 9) to air conditioner/heater mixer servo motor (Figure
20, Item 10).