AMBIENT AIR TEMPERATURE SENSOR REPLACEMENT
Figure 2. Ambient Air Temperature Sensor Installation

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -4 Page Navigation
  463    464    465    466    467  468  469    470    471    472    473  
img
.
TM 5-3805-294-23-4
0552
REMOVAL - Continued
2
1
HYEX01257
Figure 1. Ambient Air Temperature Sensor Removal.
2.
Remove ambient air temperature sensor (Figure 1, Item 2) from machine.
END OF TASK
INSTALLATION
WARNING
Ensure electrical power is off prior to working on all electrical connections. Prior to working
on or around vehicle, remove all jewelry, such as rings, ID tags, bracelets, etc. Jewelry, and
tools can catch on equipment, contact positive electrical circuits, and cause a direct short,
severe burns, or electrical shock. Failure to comply may result in injury or death to personnel.
NOTE
Install wires, connectors, and wiring harnesses as noted during removal.
1.
Install ambient air temperature sensor (Figure 2, Item 2) in machine.