Figure 20. Front Of Wiring Harness Installation
AMBIENT AIR TEMPERATURE SENSOR REPLACEMENT

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -4 Page Navigation
  461    462    463    464    465  466  467    468    469    470    471  
img
. . . . . . .
TM 5-3805-294-23-4
0551
INSTALLATION - Continued
26.
Install wiring harness connector M9 (Figure 20, Item 3) to air conditioner/heater internal and external servo
motor (Figure 20, Item 4).
27.
Install wiring harness connector B41 (Figure 20, Item 1) to air conditioner freeze control switch (Figure 20, Item
2).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Replace receiver-dryer. (WP 0538)
2.
Install cab wiring harness bracket. (WP 0572)
3.
Install cab rear tray and rear cover. (WP 0566)
4.
Install seat. (WP 0580)
5.
Install seat belt. (WP 0579)
6.
Connect negative battery cable. (WP 0521)
7.
Service air conditioner refrigerant. (WP 0540)
8.
Perform the Standard Follow-On Maintenance Instructions. (Volume 3, WP 0384)
END OF TASK
END OF WORK PACKAGE