INSTALLATION - Continued
FOLLOW-ON MAINTENANCE

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -4 Page Navigation
  460    461    462    463    464  465  466    467    468    469    470  
img
.
TM 5-3805-294-23-4
0551
INSTALLATION - Continued
4
2
3
1
5
6
10
7
9
8
HYEX02527
Figure 20. Front Of Wiring Harness Installation.
24.
Install wiring harness connector R16 (Figure 20, Item 7) to blower motor resistor/thermofuse (Figure 20, Item
8).
25.
Install wiring harness connector B42 (Figure 20, Item 5) to cab air temperature sensor (Figure 20, Item 6).
0551-18