Figure 4. Wiring Harness Installation.
Figure 1. Disconnect Wiring Harness.

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -4 Page Navigation
  893    894    895    896    897  898  899    900    901    902    903  
img
. . .
TM 5-3805-294-23-4
0618
FIELD MAINTENANCE
TRAVEL ALARM REPLACEMENT
INITIAL SETUP:
Equipment Condition (cont.)
Tools and Special Tools
Tool Kit, General Mechanic's: Automotive (Volume
Negative battery cable disconnected. (WP 0521)
Pump compartment lower access cover removed.
5, WP 0796, Table 2, Item 119)
(WP 0601)
Materials/Parts
Tags (Volume 5, WP 0797, Table 1, Item 52)
Time to Complete
0.6 Hour(s)
Tie Wraps (Volume 5, WP 0797, Table 1, Item
56)
Lockwasher (Volume 5, WP 0798, Table 1, Item
16) Qty: 2
Personnel Required
Construction Equipment Repairer 91L (1)
References
TM 5-3805-294-24P: Fig. 143 (Volume 5,
WP 0794)
DA FORM 5988-E or DA FORM 2404 (Volume 5,
WP 0794)
Equipment Condition
Machine safely parked and shut down
(TM 5-3805-294-10). (Volume 5, WP 0794)
REMOVAL
WARNING
Ensure electrical power is off prior to working on all electrical connections. Prior to working
on or around vehicle, remove all jewelry, such as rings, ID tags, bracelets, etc. Jewelry, and
tools can catch on equipment, contact positive electrical circuits, and cause a direct short,
severe burns, or electrical shock. Failure to comply may result in injury or death to personnel.
NOTE
Tag and mark wires, connectors, and wiring harnesses prior to removal to ensure proper
installation.
Note position of each tie wrap and remove as required.
0618-1


Privacy Statement