TRAVEL ALARM REPLACEMENT
Figure 3. Travel Alarm Installation.

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -4 Page Navigation
  894    895    896    897    898  899  900    901    902    903    904  
img
.
TM 5-3805-294-23-4
0618
REMOVAL - Continued
1.
Disconnect wiring harness connector H4 (Figure 1, Item 1) from travel alarm electrical connector (Figure 1,
Item 2).
2
1
3
HYEX00271
Figure 1. Disconnect Wiring Harness.
2.
Remove travel alarm electrical connector (Figure 1, Item 2) from bracket holder (Figure 1, Item 3).
3.
Remove two screws (Figure 2, Item 4), lockwashers (Figure 2, Item 5), washers (Figure 2, Item 6), bracket
holder (Figure 2, Item 3), and travel alarm (Figure 2, Item 7) from frame (Figure 2, Item 8). Discard lockwashers.
4
5
6
3
7
8
HYEX00889
Figure 2.
Remove Travel Alarm.
END OF TASK
INSTALLATION
NOTE
Install tie wraps as required.