Figure 1. Pump Compartment Travel Alarm Wiring Harness Removal.
Figure 4. Pump Compartment Travel Alarm Wiring Harness Installation.

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -4 Page Navigation
  899    900    901    902    903  904  905    906    907    908    909  
img
.
TM 5-3805-294-23-4
0619
INSTALLATION
WARNING
Ensure electrical power is off prior to working on all electrical connections. Prior to working
on or around vehicle, remove all jewelry, such as rings, ID tags, bracelets, etc. Jewelry, and
tools can catch on equipment, contact positive electrical circuits, and cause a direct short,
severe burns, or electrical shock. Failure to comply may result in injury or death to personnel.
NOTE
Install tie wraps as required.
1.
Route harness from engine compartment through machine frame to pump compartment as noted prior to
removal.
2.
Connect travel alarm wiring harness connector H4 (Figure 3, Item 1) to machine wiring harness connector W2
(Figure 3, Item 4).
3
4
HYEX01271
Figure 3. Engine Compartment Travel Alarm Wiring Harness Installation.
3.
Connect travel alarm harness connector H4 (Figure 4, Item 1) to travel alarm electrical connector (Figure 4,
Item 2) in pump compartment.
0619-3