TM 5-3805-294-23-4
0627
ARM REDUCED LEAKAGE VALVES REMOVAL
13.
Remove two O-rings (Figure 1, Item 17), O-ring (Figure 1, Item 18), and O-ring (Figure 1, Item 19) from between
housing (Figure 1, Item 16) and control valve (Figure 1, Item 3). Discard O-rings.
14.
Remove spring (Figure 1, Item 20) from control valve (Figure 1, Item 3).
15.
Remove poppet (Figure 1, Item 21) from control valve (Figure 1, Item 3).
END OF TASK
ARM REDUCED LEAKAGE VALVES INSTALLATION
WARNING
1.
Lightly lubricate poppet (Figure 2, Item 21) with clean oil.
0627-4