• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
ARCTIC HEATER 7-DAY TIMER DISPLAYS ERROR CODE. -- CONTINUED
ETHER START WILL NOT WORK.

Maintenance Manual For Interim High-Mobility Engineer Excavator
Page Navigation
  145    146    147    148    149  150  151    152    153    154    155  
img
. . . .
TM 5-2420-230-24-1
Table 3-6. Unit Troubleshooting Table. -- Continued
Malfunction
Test or Inspection
Corrective Action
ARCTIC HEATER 7-DAY TIMER DISPLAYS ERROR CODE. -- CONTINUED
Step 6.
Check arctic heater air intake (9) and exhaust pipe (10) for damage or blockage.
If air intake (9) or exhaust pipe (10) is blocked, remove blockage.
If exhaust pipe (10) is damaged, replace exhaust pipe (Para 20-5).
Step 7.
Test fuel metering pump (8) (Para 20-9).
If fuel metering pump (8) fails test, replace fuel metering pump (Para 20-9).
If fuel metering pump (8) passes, replace flame sensor (Para 20-8).