FLAME SENSOR REPLACEMENT. - Continued
FUEL METERING PUMP REPLACEMENT. - Continued

Maintenance Manual For Interim High-Mobility Engineer Excavator
Page Navigation
  690    691    692    693    694  695  696    697    698    699    700  
img
. . . . . . . . . . . .
TM 5-2420-230-24-1
20-9. FUEL METERING PUMP REPLACEMENT.
This Task Covers:
a. Removal
b. Installation
c. Bleeding and Testing
d. Follow-On Maintenance
INITIAL SETUP
Test Equipment
Equipment Conditions
None
TM or Para
Condition Description
TM 5-2420-230-10
Vehicle positioned on level
ground.
Tools and Special Tools
Cylinder, graduated, Item 20.1, Appendix B
TM 5-2420-230-10
Parking brake applied.
Tool kit, general mechanics, Item 38, Appendix B
TM 5-2420-230-10
Engine shut OFF.
TM 5-2420-230-10
Electrical master switch OFF.
TM 5-2420-230-10
"Do Not Operate" tag attached
Materials/Parts
Tags, identification, Item 63, Appendix C
to ignition switch.
Personnel Required
Drawings Required
MOS 62B, Construction Equipment Repairer
TM 5-2420-230-24P Figure 207
References
Estimated Time to Complete Task
None
Refer to MAC in Appendix B
a. Removal.
NOTE
Tag all wires and tubes and note their positions before removal.
(1)
Remove two screws (1), washers (2), and arctic
heater cover (3) from arctic heater box (4).
Change 1
20-31