FLAME SENSOR REPLACEMENT.
FUEL METERING PUMP REPLACEMENT.

Maintenance Manual For Interim High-Mobility Engineer Excavator
Page Navigation
  689    690    691    692    693  694  695    696    697    698    699  
img
.
TM 5-2420-230-24-1
b. Installation.
NOTE
Ensure all wires are reconnected to
positions noted prior to removal.
Position holder as noted prior to removal.
(1)
Position holder (5) on glow pin (7).
(2)
Install holder (5) on air blower (6) with flame
sensor (4).
(3)
Using an electrical contact tool, install two
wires (2) on connector (3).
(4)
Install exhaust cover (1).
c. Follow-On Maintenance.
Install control unit (Para 20-7).
END OF TASK