FUEL METERING PUMP REPLACEMENT. - Continued
FUEL METERING PUMP REPLACEMENT. - Continued

Maintenance Manual For Interim High-Mobility Engineer Excavator
Page Navigation
  693    694    695    696    697  698  699    700    701    702    703  
img
TM 5-2420-230-24-1
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment and injury or death to personnel may occur.
(8)
Connect connector (10) with retaining clip (9).
Fuel pump needs to be mounted at a 15 degree minimum angle from horizontal in order to prevent air
or vapor blockage in pump. Failure to comply will result in damage to equipment.
(9)
Install pump bracket (7) on arctic heater base (4) with screw (8), washer (6), and nut (5), ensuring that
fuel pump (14) is at a 15 degree minimum angle from horizontal.
(10) Bleed arctic heater fuel system.