Table 3-6. Unit Troubleshooting Table. -- Continued
Malfunction
Test or Inspection
Corrective Action
ETHER START WILL NOT WORK. -- CONTINUED
Step 5.
Check continuity of jumper wire (5) between starter button (6) and ether pushbutton (7).
If jumper wire (5) does not have continuity, replace jumper wire (Para 20-14).
Step 6.
Check continuity of ether pushbutton (7).
If ether pushbutton (7) does not have continuity, replace ether pushbutton (Para 20-14).
Step 7.
Check continuity of wire (8) between ether pushbutton (7) and valve assembly (2).
If wire (8) does not have continuity, replace wire (Para 20-13).
Step 8.
Check tube (9) between valve assembly (2) and atomizer (10).
If tube (9) is crimped or damaged, replace tube (Para 20-13).
Step 9.
Check atomizer (10) for blockage or damage.
If atomizer (10) is blocked, clear blockage.
If atomizer (10) is damaged, replace atomizer (Para 20-13).
3-117