TM 5-2420-230-24-1
Table 3-6. Unit Troubleshooting Table. -- Continued
Malfunction
Test or Inspection
Corrective Action
ETHER START WILL NOT WORK. -- CONTINUED
Step 5.
Check continuity of jumper wire (5) between starter button (6) and ether pushbutton (7).
If jumper wire (5) does not have continuity, replace jumper wire (Para 20-14).
Step 6.
Check continuity of ether pushbutton (7).
If ether pushbutton (7) does not have continuity, replace ether pushbutton (Para 20-14).
Step 7.
Check continuity of wire (8) between ether pushbutton (7) and valve assembly (2).
Step 8.
Check tube (9) between valve assembly (2) and atomizer (10).
Step 9.
Check atomizer (10) for blockage or damage.
If atomizer (10) is blocked, clear blockage.
3-117