TM 5-2420-230-24-1
Hydraulic fluid (Dexron III) is TOXIC. Wear protective goggles and gloves; use only in
well-ventilated area; avoid contact with skin, eyes, and clothes. Skin and clothing that come in contact
with hydraulic oil should be washed immediately. Saturated clothing should be removed immediately.
Failure to comply may result in injury to personnel.
NOTE
Ensure all hoses and tubes are disconnected and clear before removal.
Remove cable ties as necessary.
Tag all hoses and tubes and note their positions before removal. Note positions of T-fittings prior to
removal.
Cap and plug all tubes, hoses, and fittings upon removal.
(3)
Place drain pan under charging pump (6).
(4)
Disconnect fan motor supply tube (7) from hydraulic pump (8).
(5)
Disconnect hose (9) from fitting (10).
(6)
Disconnect hose (11) from T-fitting (12).
(7)
Disconnect two lines (13) and (14) from T-fitting (15).
(8)
Remove fitting (10), T-fitting (12), and T-fitting (15) from charging pump (6).
Change 1
4-39