CHARGING PUMP REPLACEMENT.
CHARGING PUMP REPLACEMENT. - Continued

Maintenance Manual For Interim High-Mobility Engineer Excavator
Page Navigation
  188    189    190    191    192  193  194    195    196    197    198  
img
TM 5-2420-230-24-1
Hydraulic fluid (Dexron III) is TOXIC. Wear protective goggles and gloves; use only in
well-ventilated area; avoid contact with skin, eyes, and clothes. Skin and clothing that come in contact
with hydraulic oil should be washed immediately. Saturated clothing should be removed immediately.
Failure to comply may result in injury to personnel.
NOTE
Ensure all hoses and tubes are disconnected and clear before removal.
Remove cable ties as necessary.
Tag all hoses and tubes and note their positions before removal. Note positions of T-fittings prior to
removal.
Cap and plug all tubes, hoses, and fittings upon removal.
(3)
Place drain pan under charging pump (6).
(4)
Disconnect fan motor supply tube (7) from hydraulic pump (8).
(5)
Disconnect hose (9) from fitting (10).
(6)
Disconnect hose (11) from T-fitting (12).
(7)
Disconnect two lines (13) and (14) from T-fitting (15).
(8)
Remove fitting (10), T-fitting (12), and T-fitting (15) from charging pump (6).