TM 5-2420-230-24-1
a. Removal.
Hot parts can burn personnel. Let hot parts cool before starting work. Avoid contact with hot oil.
Failure to comply may result in serious injury.
Hydraulic fluid (Dexron III) is TOXIC. Wear protective goggles and gloves; use only in well-
ventilated area; avoid contact with skin, eyes, and clothes. Skin and clothing that come in contact
with hydraulic oil should be washed immediately. Saturated clothing should be removed
immediately. Failure to comply may result in injury to personnel.
NOTE
Remove cable ties as necessary.
(1)
Place drain pan beneath transmission sampling
valve (1).
(2)
Remove transmission sampling valve (1) from
vehicle.
(3)
If required, disconnect hose (3) from
adaptor (2) and elbow (4).
(4)
If required, remove adaptor (2) and elbow (4)
from vehicle.
b. Installation.
Adhesives, solvents, and sealing compounds
burn easily and give off vapors that are
harmful to the skin and clothing. To avoid
injury or death, keep away from open fire
when using these materials, and use only in
well-ventilated areas. If adhesives, solvents, or
sealing compounds contact the skin or
clothing, wash immediately with soap and
water, and rinse thoroughly. Failure to comply
may result in injury or death to personnel.
NOTE
Install cable ties as necessary.
(1)
If removed, apply sealing compound and install elbow (4) and adaptor (2) on vehicle.
(2)
If removed, apply sealing compound and install hose (3) on elbow (4) and adaptor (2).
(3)
Apply sealing compound and install valve (1) on vehicle.
c. Follow-On Maintenance.
END OF TASK