TM 5-2420-230-24-1
This Task Covers:
a. Removal
b. Installation
c. Follow-On Maintenance
INITIAL SETUP
Test Equipment
References
None
None
Tools and Special Tools
Equipment Conditions
TM or Para
Condition Description
Engine access panel removed.
Fire wall cover removed.
Hood raised.
Materials/Parts
Hydraulic pressure relieved.
Drawings Required
Personnel Required
Estimated Time to Complete
MOS 62B, Construction Equipment Repairer
a. Removal.
Hydraulic fluid (Dexron III) is TOXIC. Wear
protective goggles and gloves; use only in
well ventilated area; avoid contact with skin,
eyes, and clothes. Skin and clothing that
come in contact with hydraulic oil should be
washed immediately. Saturated clothing
should be removed immediately. Failure to
comply may result in injury to personnel.
NOTE
Tag all hoses and wires, and note their
positions before removal.
Remove cable ties as necessary.
Cap and plug all tubes, hoses and fittings
upon removal.
(1)
Position drain beneath inlet line (1), and
remove inlet line from FEL valve block (2).