TM 5-2420-230-24-1
NOTE
Ensure T-fittings, lines, and hoses are installed to position noted prior to removal.
Install cable ties as necessary.
(6)
Install T-fitting (15), T-fitting (12), and
fitting (10) on charging pump (6).
(7)
Connect two lines (14) and (13) to
T-fitting (15).
(8)
Connect hose (11) to T-fitting (12).
(9)
Connect hose (9) to fitting (10).
(10) Connect fan motor supply tube (7) to
hydraulic pump (8).
(11) Install clamp (5) with two bolts (4).
(12) Install clamp (3) and cushion clip (2) with
two bolts (1).
c. Follow-On Maintenance.
END OF TASK
4-41
Change 1