TM 5-2420-230-24-1
b. Installation.
Adhesives, solvents, and sealing compounds burn easily and give off vapors that are harmful to the
skin and clothing. To avoid injury or death, keep away from open fire when using these materials, and
use only in well-ventilated areas. If adhesives, solvents, or sealing compounds contact the skin or
clothing, wash immediately with soap and water, and rinse thoroughly. Failure to comply may result in
injury or death to personnel.
Cleanliness is essential for correct and safe operation of the hydraulic system. Ensure dirt and debris is
not allowed to enter hydraulic system. Failure to comply may result in damage to equipment.
(1)
If removed, apply Loctite 567 on two adaptors (6) and install on hose reel (11).
(2)
Install cap (10) and nipple (9) on hose assembly (4).
(3)
Install cap (8) and coupler (7) on hose assembly (4).
NOTE
Ensure all hoses are reconnected to positions noted prior to removal.
Ensure female coupler side of hose assembly is installed on return side of hose reel.
(4)
Install hose assembly (4) on two adaptors (6).
10-87
Change 1