TM 5-2420-230-24-1
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment and injury or death to personnel may occur.
(1)
Remove screw (1) from selector (2).
(2)
Remove selector (2) from electrical master
switch (3).
(3)
Remove nut (4) and washer (5) from
electrical master switch (3).
(4)
Remove electrical master switch (3) from
mount (6).
(5)
Remove nut (7), washer (8), and wire (9)
from electrical master switch (3).
(6)
Remove nut (10), washer (11), and wire (12)
from electrical master switch (3).
(7)
Remove nut (13), washer (14), and two
wires (15) from electrical master switch (3).
b. Installation.
NOTE
Ensure all wires are reconnected to positions noted prior to removal.
Install cable ties as necessary.
(1)
Install wire (9), washer (8), and nut (7) on electrical master switch (3).
(2)
Install wire (12), washer (11), and nut (10) on electrical master switch (3).
(3)
Install two wires (15), washer (14), and nut (13) on electrical master switch (3).
(4)
Position electrical master switch (3) into mount (6).
(5)
Install washer (5) and nut (4) on electrical master switch (3).
(6)
Install selector (2) on electrical master switch (3).
(7)
Install screw (1) on selector (2).
c. Follow-On Maintenance.
(1)
Start engine to check electrical master switch for proper operation (TM 5-2420-230-10).
(2)
Shut OFF engine (TM 5-2420-230-10).
(3)
Remove "Do Not Operate" tag from ignition switch (TM 5-2420-230-10).