NATO SLAVE RECEPTACLE REPLACEMENT.
ALTERNATOR REPLACEMENT.

Maintenance Manual For Interim High-Mobility Engineer Excavator
Page Navigation
  412    413    414    415    416  417  418    419    420    421    422  
img
.
TM 5-2420-230-24-1
b. Installation.
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment and injury or death to personnel may occur.
NOTE
Ensure all wires are reconnected to positions noted prior to removal.
Install cable ties as necessary.
(1)
Install NATO slave receptacle (10) with four bolts (9), washers (8), and new self-locking nuts (7). Tighten nuts.
(2)
Install positive (+) battery cable (3) on NATO slave receptacle with new lockwasher (2) and screw (1).
(3)
Install negative (-) battery cable (6) on NATO slave receptacle with new lockwasher (5) and screw (4).
c. Follow-On Maintenance.
Remove "Do Not Operate" tag from ignition switch (TM 5-2420-230-10).
END OF TASK