ALTERNATOR REPLACEMENT.
STARTER MOTOR REPLACEMENT.

Maintenance Manual For Interim High-Mobility Engineer Excavator
Page Navigation
  414    415    416    417    418  419  420    421    422    423    424  
img
. . . .
TM 5-2420-230-24-1
b. Installation.
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment and injury or death to personnel may occur.
Steps in the installation of the alternator are the reverse of those in the removal procedure with attention given to the
following points:
NOTE
Ensure all wires are reconnected to positions noted prior to removal.
Install cable ties as necessary.
(1)
Install pulley on alternator, if required.
(2)
Ensure electrical connections are reattached correctly and securely.
(3)
Ensure mounting bolts and nuts are tightened to 40 lbf/ft (54 Nm).
c. Follow-On Maintenance.
(1)
Install drive belt (Para 4-6).
(2)
Start engine and check VOLTMETER to verify proper alternator operation (TM 5-2420-230-10).
(3)
Shut OFF engine (TM 5-2420-230-10).
(4)
Remove "Do Not Operate" tag from ignition switch (TM 5-2420-230-10).
END OF TASK
12-14
Change 1


Privacy Statement