AUXILIARY DEFROSTER HEATER MAINTENANCE. - Continued
MILITARY LOAD CLASSIFICATION (MLC) PLACARD REPLACEMENT.

Maintenance Manual For Interim High-Mobility Engineer Excavator
Page Navigation
  574    575    576    577    578  579  580    581    582    583    584  
img
. . .
TM 5-2420-230-24-1
(5)
Connect two wires (9) and (8) to motor (10).
(6)
Connect connector (6) to motor resistor (7).
(7)
Install grille (5) on defroster assembly (4).
(8)
Install duct (2) on adapter (3) with two screws (1).
e. Follow-On Maintenance.
(1)
Fill cooling system (Para 9-4).
(2)
Start engine (TM 5-2420-230-10) and check for leaks.
(3)
Shut OFF engine (TM 5-2420-230-10).
END OF TASK
13-79