AIR TANK REPLACEMENT. - Continued
AIR TANK REPLACEMENT. - Continued

Maintenance Manual For Interim High-Mobility Engineer Excavator
Page Navigation
  598    599    600    601    602  603  604    605    606    607    608  
img
TM 5-2420-230-24-1
b. Installation.
NOTE
Left and right air tanks are installed in the same
manner.
(1)
Air tank (9.7L).
(a)
Install fittings, if required.
(b)
Position air tank (2) into air tank
clamps (4).
(c)
Install quick accessories coupling (1) to air
tank (2).
(d)
Tighten two new self-locking nuts (3).
(2)
Air tank (13.8L) or (20L).
(a)
Install fittings, if required.
(b)
Position air tank (7).
(c)
Install two air tank cables (6).
(d)
Install two new self-locking nuts (5).
(e)
Install air lines onto air tank (7).