Electrical Outlet
Ether Start

Maintenance Manual For Interim High-Mobility Engineer Excavator
Page Navigation
  671    672    673    674    675  676  677    678    679    680    681  
img
.
TM 5-2420-230-24-1
(7)
Remove 0.25 in. (6 mm) of insulation from
end of three electrical outlet wires (109),
(110), and (111).
(8)
Connect end of ridged electrical outlet
wire (109) with ends of black bulk wire (72)
and black trickle charger wire (95) using
wire connector (112).
(9)
Connect end of green electrical outlet
wire (110) with ends of green bulk wire (73)
and green trickle charger wire (96) using
wire connector (113).
(10) Connect end of smooth electrical outlet
wire (111) with ends of white bulk wire (74)
and white trickle charger wire (97) using
wire connector (114).
(11) Install electrical tape on connections.
(12) Cover bulk wires (72), (73), and (74) with wire sleeving (115), and secure as necessary with cable ties.
(13) Install hydraulic step plate (98) (Para 13-15).