TM 5-2420-230-24-1
(24) Loosen two clamps (146) and remove hose (147) from elbow (148) and tube (149). Discard hose.
(25) Disconnect tube (150) from fitting (151) and loosen screw (152).
(26) Remove T-fitting (153) from rear side of air cross connection (154).
(27) Remove plug (155) from front side of air cross connection (154).
(28) Install T-fitting (153) in front side of air cross connection (154).
(29) Connect tube (150) on fitting (151) and tighten screw (152).
(30) Install 18-in. (457 mm) hose (156) on tube (149) and elbow (148) with two clamps (146).
(31) Remove tube fitting (157) from atomizer (158).
(32) Install atomizer (158) on rear side of air cross connection (154).
(33) Install tube (130) on atomizer (158) with tube fitting (157). Tighten tube fitting approximately one turn after it is
finger tight.
Change 1