• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
REMOVE AND INSTALL BOOM CYLINDER CONTROLLED LOAD LOWERING VALVE - Continued
REMOVE AND INSTALL BOOM CYLINDER - Continued

Technical Manual For Hydraulic Excavator Model 330Lcr 2
Page Navigation
  818    819    820    821    822  823  824    825    826    827    828  
img
.
TM 5-3805-281-24-2
Hydraulic System
REMOVE AND INSTALL BOOM CYLINDER
33
NOTE: Procedure is the same for both left and right
3360
boom cylinders; right boom cylinder is shown.
149
1. Park machine on a firm, level surface.
2. Retract arm and bucket cylinders. Lower boom so
bucket is on ground.
3. Stop engine.
CED,OUOE026,9
1918JUN981/5
CAUTION: The hydraulic oil tank is pressurized.
High pressure release of oil from pressurized
system can cause serious burns or penetrating
injury. Release pressure from tank by loosening
vent plug. It is not necessary to remove vent
plug.
4. Loosen vent plug (A) to release air pressure from
hydraulic oil tank.
A--Vent Plug
Continued on next page
CED,OUOE026,9
1918JUN982/5
19-176