REMOVE AND INSTALL ARM CYLINDER
33
1. Park machine on a firm, level surface.
3360
153
2. Retract arm and bucket cylinders. Lower boom so
bucket is on ground.
3. Stop engine.
CED,OUOE026,10 1918JUN981/5
CAUTION: The hydraulic oil tank is pressurized.
High pressure release of oil from pressurized
system can cause serious burns or penetrating
injury. Release pressure from tank by loosening
vent plug. It is not necessary to remove vent
plug.
4. Loosen vent plug (A) to release air pressure from
hydraulic oil tank.
A--Vent Plug
Continued on next page