TM 5-3805-294-23-1
0115
Table 1. Engine Cranks/Will Not Start - Continued.
Test or Inspection
Corrective Action
Malfunction
2.
Visually inspect monitor to
verify at least 1/4 tank of fuel is
available (TM 5-3805-294-10).
(Volume 5, WP 0794)
3.
Turn key switch OFF position
1.
If fuel level is low, add fuel (TM
(TM 5-3805-294-10). (Volume
5-3805-294-10). (Volume 5,
5, WP 0794)
WP 0794) Restore machine to
original condition.
2.
If fuel level is OK, proceed to
Malfunction 3.
1.
Remove air filters and hoses.
3.
Air Intake
Restricted With
(Volume 3, WP 0456)
Debris or Foreign
Objects.
2.
Visually inspect air filters,
1.
If restricted, remove debris or
housing, and hoses for debris
foreign objects. Restore
and foreign objects.
machine to original condition.
2.
If not restricted, proceed to
Malfunction 4.
1.
Install air filters and hoses.
4.
(Volume 3, WP 0456)
Restricted.
2.
Visually inspect exhaust pipes
1.
If restricted, remove debris or
foreign objects. Restore
restrictions. (Volume 3,
machine to original condition.
WP 0482)
2.
pipes/muffler. (Volume 3,
WP 0482) Restore machine to
original condition.
3.
If not restricted or damaged,
proceed to Malfunction 5.
1.
Remove battery covers.
5.
Batteries State of
Charge is Below 22
(Volume 4, WP 0496)
Volts.
2.
Measure voltage (Volume 3,
1.
If reading is at least 22 volts,
proceed to Malfunction 6.
WP 0369) of both batteries
between positive and negative
2.
If reading is less than 22 volts,
terminals. (Volume 5,
replace batteries. (Volume 4,
WP 0800, Figure 5) Note
WP 0496) Restore machine to
reading.
original condition.
0115-2