Table 1. Engine Cranks/Will Not Start - Continued
Table 1. Engine Cranks/Will Not Start - Continued

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  761    762    763    764    765  766  767    768    769    770    771  
img
TM 5-3805-294-23-1
0115
Table 1. Engine Cranks/Will Not Start - Continued.
Test or Inspection
Corrective Action
Malfunction
3.
Select Dearborn Protocol
Adapter (DPA 4+) USB for the
Readings Adapter, and select
OK. (Volume 3, WP 0363)
4.
Select Engine Control Unit
(ECU) Only. (Volume 3,
WP 0363)
5.
Under Connected Data Points,
select ECU - (shown with
engine serial number).
(Volume 3, WP 0363)
6.
Under ECU - (shown with
engine serial number), select
ECU - Data List - All. (Volume
3, WP 0363)
7.
Select following data points
under ECU - Data List - All:
(Volume 3, WP 0363)
a. Crankshaft Position
Signal Status
b. Camshaft Position
Signal Status
c. Engine Speed Indicated
by Crankshaft Sensor
d. Engine Speed Indicated
by Camshaft Sensor
e. Crankshaft Position
Signal Improper Pattern
Indicator
f. Camshaft Position
Signal Improper Pattern
Indicator
g. Crankshaft Position
Signal Noise Indicator
h. Camshaft Position
Signal Noise Indicator
8.
Monitor and record data
points (Volume 3, WP 0364) in
Service ADVISOR while
cranking engine for 15
seconds. (TM 5-3805-294-10)
(Volume 5, WP 0794)
0115-5