Table 1. Glow Plug Check - Continued
Table 1. Glow Plug Check - Continued

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  883    884    885    886    887  888  889    890    891    892    893  
img
TM 5-3805-294-23-1
0129
Table 1. Glow Plug Check - Continued.
Test or Inspection
Corrective Action
Malfunction
2.
Measure resistance (Volume
1.
If continuity is present,
proceed to Malfunction 31.
3, WP 0369) between relay
K16 wire terminal P04 (Volume
2.
If continuity is not present,
5, WP 0800, Figure 208) and
replace fuse wiring harness.
relay K19 terminal B. (Volume
(Volume 4, WP 0512)
5, WP 0800, Figure 209) Note
Reconnect all connectors and
reading.
proceed to Malfunction 23.
1.
Turn key switch to ON position,
31.
22 - 28 Volts Not
but DO NOT START ENGINE
Present Between
(TM 5-3805-294-10). (Volume
Battery Relay K19
Terminal B and
5, WP 0794)
Ground.
2.
Measure voltage (Volume 3,
WP 0369) between relay K19
terminal B (Volume 5,
WP 0800, Figure 209) and a
known good ground. Note
reading.
3.
Turn key switch to OFF
1.
If voltage is present, problem
position (TM 5-3805-294-10).
may have been missed during
troubleshooting procedures.
(Volume 5, WP 0794)
Restart procedure at
Malfunction 1.
2.
If voltage is not present,
replace machine wiring
harness. (Volume 4,
WP 0516) Reconnect all
connectors and proceed to
Malfunction 23.
1.
Disconnect engine wiring
32.
Engine Wiring
harness connector J03.
Harness Connector
J03 Has Damage or
(Volume 5, WP 0800, Figure
Loose Sockets.
48)
2.
Visually inspect engine wiring
1.
If damaged or has loose
harness connector J03 for
sockets, replace engine wiring
damage and loose sockets.
harness. (Volume 4,
WP 0510) Reconnect all
connectors and proceed to
Malfunction 23.
2.
If not damaged and does not
have loose sockets, proceed to
Malfunction 33.
0129-13