Figure 13. Latch Panel Cover Installation
Figure 1. Cab Door Removal.

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -4 Page Navigation
  486    487    488    489    490  491  492    493    494    495    496  
img
.
TM 5-3805-294-23-4
0556
FIELD MAINTENANCE
CAB DOOR REPLACEMENT
INITIAL SETUP:
References (cont.)
Tools and Special Tools
Tool Kit, General Mechanic's: Automotive (Volume
TM 5-3805-295-13&P (Volume 5, WP 0794)
DA FORM 5988-E or DA FORM 2404 (Volume 5,
5, WP 0796, Table 2, Item 119)
Lifting Device, Minimum Capacity 500 lb
WP 0794)
Materials/Parts
Equipment Condition
Machine safely parked and shut down
Lockwasher (Volume 5, WP 0798, Table 1, Item
(TM 5-3805-294-10). (Volume 5, WP 0794)
17) Qty: 1
Time to Complete
Personnel Required
Construction Equipment Repairer 91L (2)
0.7 Hour(s)
References
TM 5-3805-294-24P: Fig. 98 (Volume 5,
WP 0794)
REMOVAL
NOTE
If HYEX is equipped with a Supplemental Armor Set, refer to and use procedure found in TM
5-3805-295-13&P.
1.
Remove two bolts (Figure 1, Item 1) and lockwashers (Figure 1, Item 2) from cab lower hinge (Figure 1, Item
3) and cab door (Figure 1, Item 4). Discard lockwashers.
0556-1