TM 5-3805-294-23-4
0640
REMOVAL - Continued
4.
Remove auxiliary circuit shut-off valve (Figure 1, Item 4) and fitting (Figure 1, Item 5) from fitting (Figure 1,
Item 6).
5.
Remove two bolts (Figure 1, Item 7) and washers (Figure 1, Item 8) from auxiliary circuit shut-off valve (Figure
1, Item 4) and arm (Figure 1, Item 9).
6.
Remove O-ring (Figure 1, Item 10) from fitting (Figure 1, Item 6). Discard O-ring.
7.
Remove fitting (Figure 1, Item 5) and O-ring (Figure 1, Item 11) from auxiliary circuit shut-off valve (Figure 1,
Item 4).
8.
Remove O-ring (Figure 1, Item 11) from fitting (Figure 1, Item 5). Discard O-ring.
END OF TASK
0640-3