Figure 1. Auxiliary Circuit Shut-Off Valve Removal.
Figure 2. Auxiliary Circuit Shut-Off Valve Installation.

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -4 Page Navigation
  1082    1083    1084    1085    1086  1087  1088    1089    1090    1091    1092  
img
TM 5-3805-294-23-4
0640
REMOVAL - Continued
4.
Remove auxiliary circuit shut-off valve (Figure 1, Item 4) and fitting (Figure 1, Item 5) from fitting (Figure 1,
Item 6).
5.
Remove two bolts (Figure 1, Item 7) and washers (Figure 1, Item 8) from auxiliary circuit shut-off valve (Figure
1, Item 4) and arm (Figure 1, Item 9).
6.
Remove O-ring (Figure 1, Item 10) from fitting (Figure 1, Item 6). Discard O-ring.
7.
Remove fitting (Figure 1, Item 5) and O-ring (Figure 1, Item 11) from auxiliary circuit shut-off valve (Figure 1,
Item 4).
8.
Remove O-ring (Figure 1, Item 11) from fitting (Figure 1, Item 5). Discard O-ring.
END OF TASK
0640-3