AUXILIARY CIRCUIT SHUT-OFF VALVES REPLACEMENT
REMOVAL - Continued

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -4 Page Navigation
  1081    1082    1083    1084    1085  1086  1087    1088    1089    1090    1091  
img
.
TM 5-3805-294-23-4
0640
REMOVAL - Continued
WARNING
Hydraulic system operates at high pressures and temperatures. Always allow hydraulic oil to
cool and relieve pressure in hydraulic reservoir before working on hydraulic system. Wear
eye protection and gloves to prevent injury. Open lines and hoses slowly and wait for any
residual pressure to relieve before continuing to open lines and hoses. Failure to comply may
result in injury or death to personnel.
CAUTION
Wipe area clean around all fluid connections prior to removal. Cap and plug all hoses, lines,
fittings, and ports during removal to prevent contamination of system components. Systems
must be kept clean from contaminants. Failure to comply may result in damage to equipment.
NOTE
Left side and right side auxiliary circuit shut-off valves are removed in the same way.
Right side auxiliary circuit shut-off valve shown.
Position drain pan under hoses being removed.
Tag and mark hoses and fittings prior to removal to ensure proper installation.
Note position of each tie wrap and remove as required.
1.
Remove hose (Figure 1, Item 1) from fitting (Figure 1, Item 2).
6
10
9
5
11
4
3
2
8
1
7
HYEX01236
Figure 1.
Auxiliary Circuit Shut-Off Valve Removal.
2.
Remove fitting (Figure 1, Item 2) and O-ring (Figure 1, Item 3) from auxiliary circuit shut-off valve (Figure 1,
Item 4).
3.
Remove O-ring (Figure 1, Item 3) from fitting (Figure 1, Item 2). Discard O-ring.