CHAPTER 7 FUEL SYSTEM
RESTORE IHMEE TO OPERATIONAL READINESS. - Continued

Maintenance Manual For Interim High-Mobility Engineer Excavator
Page Navigation
  266    267    268    269    270  271  272    273    274    275    276  
img
. . . . . . . . . . . . . . . . . . .
TM 5-2420-230-24-1
7-3. RESTORE IHMEE TO OPERATIONAL READINESS.
Upon completion of maintenance activities, restore power and return vehicle to operational readiness by doing the following:
(1)
Place electrical master switch in ON position (TM 5-2420-230-10).
(2)
Remove "Do Not Operate" tag from ignition switch (TM 5-2420-230-10).
(3)
Ensure parking brake is applied (TM 5-2420-230-10).
(4)
Start engine (TM 5-2420-230-10).
(5)
Raise FEL, remove maintenance arm, and lower FEL to ground or travel position as required
(TM 5-2420-230-10).
(6)
Complete necessary documents and return IHMEE to relevant authority.
7-4. BLEEDING FUEL SYSTEM.
This Task Covers:
a. Bleeding
b. Follow-On Maintenance
INITIAL SETUP
Test Equipment
Equipment Conditions
None
TM or Para
Condition Description
TM 5-2420-230-10
Vehicle positioned on level
ground.
Tools and Special Tools
Pan, drain, Item 29, Appendix B
TM 5-2420-230-10
Parking brake applied.
Tool kit, general mechanics, Item 38, Appendix B
TM 5-2420-230-10
Engine shut OFF.
TM 5-2420-230-10
Electrical master switch OFF.
TM 5-2420-230-10
"Do Not Operate" tag attached
Materials/Parts
Cloth, lint-free, Item 10, Appendix C
to ignition switch.
TM 5-2420-230-10
Hood raised.
Personnel Required
MOS 62B, Construction Equipment Repairer (2)
Drawings Required
TM 5-2420-230-24P Figure 35
References
None.
Estimated Time to Complete Task
Refer to MAC in Appendix B