TM 5-2420-230-24-1
a. Removal.
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment and injury or death to personnel may occur.
NOTE
Tag all wires and note their positions before removal.
Remove cable ties as required.
(1)
Remove four bolts (1) from charge equalizer (2).
(2)
Disconnect wire harness (3) from charge
equalizer (2).
b. Installation.
NOTE
Ensure all hoses, wires, and tubes are reconnected
to positions noted prior to removal.
Install cable ties as required.
(1)
Install charge equalizer (2) with four bolts (1).
(2)
Connect wire harness (3) into charge equalizer (2).
c. Follow-On Maintenance.