AUXILIARY DEFROSTER DUCTING REPLACEMENT.
AUXILIARY DEFROSTER HEATER MAINTENANCE.

Maintenance Manual For Interim High-Mobility Engineer Excavator
Page Navigation
  566    567    568    569    570  571  572    573    574    575    576  
img
TM 5-2420-230-24-1
(3)
Remove insulation (5) from duct (6). Discard insulation.
(4)
Remove two screws (7) and duct (2) from duct (6).
(5)
Remove insulation (8) from duct (9). Discard insulation.
(6)
Remove two screws (10) and duct (6) from duct (9).
(7)
Remove two screws (11) and duct (9) from duct (12).
(8)
Remove insulation (13) from duct (12). Discard insulation.
(9)
Remove two screws (14) and duct (12) from adapter (15).
b. Installation
(1)
Install duct (12) on adapter (15) with two screws (14).
(2)
Install duct (9) on duct (12) with two screws (11).
(3)
Install duct (6) on duct (9) with two screws (10).
(4)
Install duct (2) on duct (6) with two screws (7).
(5)
Install new insulation (13) on duct (12).
(6)
Install new insulation (8) on duct (9).
(7)
Install new insulation (5) on duct (6).
13-71