Locked Timed Injection Pump - Installation - Continued
Injection Pumps - Unlocking (0-90) - Continued

Interim High-Mobility Engineer Excavator Nsn 2420-66-148-7692
Page Navigation
  158    159    160    161    162  163  164    165    166    167    168  
img
TM 5-2420-230-24-2
Injection Pump - Installation (0-88)
Section 0 - Engine Disassembly and Assembly - Group 00
Page 0-74
B Series Shop Manual
Injection Pumps - Unlocking (0-90)
14 mm
Loosen the Stanadyne and CAV pump lockscrew and
position the special washer with the large opening show-
ing behind the lockscrew head.
Torque Value:
20 Nm
[15 ft-lb] (CAV)
12 Nm
[ 9ft-lb] (Stanadyne)
8 mm Allen or 10 mm Hex
The special washer for the Bosch pump is wired to the
pump and must be installed under the lockscrew.
Tighten the pump lockscrew.
Torque Value: 13 Nm
[10 ft-lb]
34 mm
The Nippondenso EP9 has a plastic timing pin and spring
which is located under the cap on the outboard side of the
pump. This pin locates the pump shaft to correspond with
TDC for number one cylinder. To unlock the pump, the
spring is placed under the head of the timing pin and the
cap installed.
Torque Value: 70 Nm
[50 ft-lb]
Service Tip: If difficulty is experienced with disengaging
the plastic timing pin, use a small flat blade screwdriver
to pry the pin free.