• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. DTC 97.04 - Water in Fuel Signal Out of Range Low - Continued.
Table 1. DTC 97.04 - Water in Fuel Signal Out of Range Low - Continued.

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  120    121    122    123    124  125  126    127    128    129    130  
img
TM 5-3805-294-23-1
0019
Table 1. DTC 97.04 - Water in Fuel Signal Out of Range Low - Continued.
Test or Inspection
Corrective Action
Malfunction
3.
Select Dearborn Protocol
Adapter (DPA 4+) USB for the
Readings Adapter, and select
OK. (Volume 3, WP 0363)
4.
Select Engine Control Unit
(ECU) Only. (Volume 3,
WP 0363)
5.
Under Connected Data Points,
select ECU - (shown with
engine serial number).
(Volume 3, WP 0363)
6.
Under ECU - (shown with
engine serial number), select
ECU - Data List - All. (Volume
3, WP 0363)
7.
Under ECU - Data List - All,
select Water in Fuel Input
Voltage. (Volume 3,
WP 0363)
8.
Monitor Water in Fuel Input
Voltage while gently wiggling
engine wiring harness
between connectors J03 and
D01 and note any fluctuations
in voltage. Input voltage will
decrease to approximately 0V
when sensor circuit is shorted
to ground.
9.
When finished monitoring,
select Readings and select
Disconnect From Model(s).
(Volume 3, WP 0363)
10.
Select Yes to terminate your
readings connection. (Volume
3, WP 0363)
0019-10