Table 1. DTC 3510.03 - Sensor Supply #2 Voltage Out Of Range High
Table 1. DTC 3510.03 - Sensor Supply #2 Voltage Out Of Range High - Continued

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -1 Page Navigation
  727    728    729    730    731  732  733    734    735    736    737  
img
TM 5-3805-294-23-1
0107
Table 1. DTC 3510.03 - Sensor Supply #2 Voltage Out Of Range High - Continued.
Test or Inspection
Corrective Action
Malfunction
2.
Measure voltage (Volume 3,
WP 0369) between engine
wiring harness connector J03
socket H4 and a known good
ground. (Volume 5, WP 0800,
Figure 48) Note readings.
3.
Turn key switch to OFF
1.
If voltage is greater than 5.26V,
position (TM 5-3805-294-10).
replace engine wiring
harness. (Volume 4,
(Volume 5, WP 0794)
WP 0510) Restore machine to
original condition and perform
Harness Diagnostic Mode
Test. (Volume 3, WP 0345)
2.
If voltage is below 5.26V,
proceed to Malfunction 3.
Measure resistance (Volume
1.
If any measurement was less
3.
Short Circuit
than 10 ohms, replace engine
Between Engine
3, WP 0369) between engine
wiring harness. (Volume 4,
Wiring Harness
wiring harness connector J03
Connector J03
socket H4 and all other sockets
WP 0510) Restore machine to
Socket H4 and All
on engine wiring harness
original condition and perform
Other Sockets On
connectors J03 (Volume 5,
Harness Diagnostic Mode
Engine Wiring
WP 0800, Figure 48) and
Test. (Volume 3, WP 0345)
Harness
J01. (Volume 5, WP 0800,
2.
If all measurements were
Connectors J01 and
Figure 46) Note readings.
greater than 10 ohms, proceed
J03.
to Malfunction 4.
1.
Disconnect engine interface
4.
Short Circuit
wiring harness connector J02.
Between Engine
Wiring Harness
(Volume 5, WP 0800, Figure
Connector J03
47)
Socket H4 and All
Other Sockets on
Engine Interface
Wiring Harness
Connector J02.
0107-3