Figure 5. Auxiliary Control Wiring Harness (W15) S35 Connect
Figure 8. Auxiliary Control Wiring Harness (W15) to Crush-all Boom Wiring Harness Installation

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -4 Page Navigation
  24    25    26    27    28  29  30    31    32    33    34  
img
.
TM 5-3805-294-23-4
0492
INSTALLATION - Continued
18
15 16
17
19
20
21
14
HYEX01288
Figure 6. Auxiliary Control Wiring Harness (W15) Relays Installation.
3.
Repeat Step (2) to install relays K32 (Figure 6, Item 20), K31 (Figure 6, Item 19), and K30 (Figure 6, Item 17),
and hardware to bracket (Figure 6, Item 18).
4.
Connect right-hand pilot control harness connection C (Figure 7, Item 13) to auxiliary control wiring harness
(W15) at connection C (Figure 7, Item 12).
12
10
13
11
HYEX01287
Figure 7. Auxiliary Control Wiring Harness (W15) Connection B and C Connect.
5.
Connect right-hand pilot control harness connection B (Figure 7, Item 11) to auxiliary control wiring harness
(W15) at connection B (Figure 7, Item 10).
6.
Install cover (Figure 8, Item 9) to frame (Figure 8, Item 6) with three washers (Figure 8, Item 8) and bolts (Figure
8, Item 7).
0492-5