Figure 4. Remove Power Delivery Wiring Harness From Cab Pillar
Figure 7. Connect Exterior Wiring Harness To Power Delivery Wiring Harness

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -4 Page Navigation
  90    91    92    93    94  95  96    97    98    99    100  
img
.
TM 5-3805-294-23-4
0501
POWER DELIVERY WIRING HARNESS REMOVAL - Continued
12
15
13
HYEX01527
Figure 5. Power Delivery Wiring Harness Removal From Interior Of Cab.
4.
Remove twine from power delivery wiring harness (Figure 5, Item 13).
5.
Disconnect cab rear work lights exterior wiring harness connector (Figure 6, Item 16) from power delivery wiring
harness connector (Figure 6, Item 17).
16
18
17
19
HYEX01763
Figure 6. Disconnect Exterior Wiring Harness From Power Delivery Wiring Harness.
6.
Disconnect cab rear work lights exterior wiring harness connector (Figure 6, Item 18) from power delivery wiring
harness connector (Figure 6, Item 19).
END OF TASK
0501-5