Figure 7. Cover and Clamp Installation
FOLLOW-ON MAINTENANCE

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -4 Page Navigation
  371    372    373    374    375  376  377    378    379    380    381  
img
. .
TM 5-3805-294-23-4
0536
INSTALLATION - Continued
1
2
3
4
5
9
8
7
6
HYEX00530
Figure 8.
Hose Installation.
WARNING
LUBRICATING OIL
10.
Lightly lubricate O-ring (Figure 8, Item 4) with clean refrigerant oil.
11.
Install O-ring (Figure 8, Item 4) to hose (Figure 8, Item 3).
12.
Install hose (Figure 8, Item 3) and O-ring (Figure 8, Item 4) to air conditioner compressor (Figure 8, Item 5)
with bolt (Figure 8, Item 1) and washer (Figure 8, Item 2).
END OF TASK
FOLLOW-ON MAINTENANCE
1.
Replace receiver-dryer. (WP 0538)
0536-9