WARNING
Upper protection guard weighs approximately 78 lb (35.5 kg). Do not attempt to lift or move
upper protection guard without the aid of an assistant and a suitable lifting device. Failure to
comply may result in injury or death to personnel.
4.
With the aid of an assistant and a suitable lifting device, install upper protection guard (Figure 2, Item 3) to
operator cab frame (Figure 2, Item 7) with four bolts (Figure 2, Item 5) and washers (Figure 2, Item 6). Do not
fully tighten bolts (Figure 2, Item 5) at this time.
5.
Apply thread lock to threads of four bolts (Figure 2, Item 1).
6.
Install four bolts (Figure 2, Item 1) and washers (Figure 2, Item 2) to attach upper protection guard (Figure 2,
Item 3) to lower protection guard (Figure 2, Item 4). Tighten bolts (Figure 2, Item 1).
7.
Tighten eight bolts (Figure 2, Item 5) and (Figure 2, Item 8).
END OF TASK
FOLLOW-ON MAINTENANCE
Perform the Standard Follow-On Maintenance Instructions. (Volume 3, WP 0384)
END OF TASK
END OF WORK PACKAGE