FOLLOW-ON MAINTENANCE
Figure 1. Barrier Grapple Actuator Removal.

Maintenance Manual For Hydraulic Excavator Type 1 With Hydraulic Thumb And Quick Latch -4 Page Navigation
  1091    1092    1093    1094    1095  1096  1097    1098    1099    1100    1101  
img
.
TM 5-3805-294-23-4
0642
FIELD MAINTENANCE
BARRIER GRAPPLE ACTUATOR REPLACEMENT
INITIAL SETUP:
References
Tools and Special Tools
TM 5-3805-294-24P: Fig. 146 (Volume 5,
Tool Kit, General Mechanic's: Automotive
WP 0794)
(Volume 5, WP 0796, Table 2, Item 119)
DA FORM 5988-E or DA FORM 2404 (Volume 5,
Goggles, Industrial (Volume 5, WP 0796, Table 2,
WP 0794)
Item 58)
Equipment Condition
Materials/Parts
Machine safely parked and shut down
Lockwashers (Volume 5, WP 0798, Table 1, Item
(TM 5-3805-294-10). (Volume 5, WP 0794)
145) Qty:  2
Time to Complete
Personnel Required
0.5 Hour(s)
Construction Equipment Repairer 91L (1)
REMOVAL
WARNING
Safety glasses must be worn when using hammer and chisel. Material can be broken off and
act as projectiles. Failure to comply may result in serious injury or death to personnel.
NOTE
Actuator is welded to frame at factory for assembly. If actuator is being replaced for the first
time, welds must be broken. Actuator does not need to be welded to frame after replacement.
1.
Remove two bolts (Figure 1, Item 1), lockwashers (Figure 1, Item 2), and nuts (Figure 1, Item 3) from actuator
assembly (Figure 1, Item 4) and upper arm assembly (Figure 1, Item 5). Discard lockwashers.