TM 5-2420-230-24-1
Tip of removal tool is very sharp. Use
caution when using tool. Failure to comply
may result in injury to personnel.
(c)
Insert removal tool into cavity (3) on
connector (1) until seated.
(d)
Pull wire (4) back through
connector (1) and remove tool.
NOTE
Do Step (e) only if terminal is still
attached to wire.
Make cut directly behind damaged
terminal.
(e)
Cut terminal (5) and wire seal (6) from wire (4). Discard terminal and seal.
(1)
Assembly.
(a)
Insert 1 in. (25 mm) of wire (4)
through new wire seal (6).
Strip wire after placing it through seal to
prevent damage to individual wire strands.
(b)
Strip end of wire (4) leaving 0.25 in.
(6 mm) of bare wire.
(c)
Insert new terminal (5) in locating hole
of crimp tool using proper hole
according to the gauge of wire (4).
(d)
Slide seal (6) down to end of insulation
on wire (4).
Change 1
12-54