Group II Terminal Repair. - Continued
FRONT WIPER MOTOR REPLACEMENT.

Maintenance Manual For Interim High-Mobility Engineer Excavator
Page Navigation
  457    458    459    460    461  462  463    464    465    466    467  
img
. . .
TM 5-2420-230-24-1
(c)
Insert new terminal (5) in locating hole of crimp tool using the proper hole according to gauge of wire (4).
(d)
Slide wire seal (6) down to end of insulation on wire (4).
NOTE
Wire and seal should be positioned so larger wings of terminal will crimp around insulation and
smaller wings will crimp around bare wire.
(e)
Position wire (4) on terminal (5).
(f)
Press handles of crimp tool together until
ratchet releases and crimp is complete.
(g)
Push new terminal (5) and wire (4)
through connector (1) until seated.
(h)
Install two secondary locks (2) on
connector (1).
(i)
Connect connector (1).
h. Follow-On Maintenance.
(1)
Start engine (TM 5-2420-230-10) and check
operation of electrical components to ensure
harness is operating correctly (TM 5-2420-230-10).
(2)
Remove "Do Not Operate" tag from ignition switch (TM 5-2420-230-10).
END OF TASK