TM 5-2420-230-24-1
(c)
Insert new terminal (5) in locating hole of crimp tool using the proper hole according to gauge of wire (4).
(d)
Slide wire seal (6) down to end of insulation on wire (4).
NOTE
Wire and seal should be positioned so larger wings of terminal will crimp around insulation and
smaller wings will crimp around bare wire.
(e)
Position wire (4) on terminal (5).
(f)
Press handles of crimp tool together until
ratchet releases and crimp is complete.
(g)
Push new terminal (5) and wire (4)
through connector (1) until seated.
(h)
Install two secondary locks (2) on
connector (1).
(i)
Connect connector (1).
h. Follow-On Maintenance.
(1)
operation of electrical components to ensure
(2)
END OF TASK
Change 1
12-57