ARCTIC HEATER ASSEMBLY MAINTENANCE. - Continued
ARCTIC HEATER ASSEMBLY MAINTENANCE. - Continued

Maintenance Manual For Interim High-Mobility Engineer Excavator
Page Navigation
  683    684    685    686    687  688  689    690    691    692    693  
img
TM 5-2420-230-24-1
d. Installation
Coolant may damage the skin. Wear protective equipment and avoid skin contact when handling coolant.
(1)
Install two coolant hoses (21) on arctic heater box (2) with two clamps (20).
(2)
Install exhaust pipe (18) on arctic heater (19) with clamp (17).
(3)
Install arctic heater box (2) on box mounting brackets (16) with four isolators (15), washers (14), and nuts (13).
No smoking, flames, sparks, or glowing or hot objects are allowed within 50 ft. (15 m) of vehicle.
Fire or explosion may cause personal injury or death.
Fuel and oil are slippery and can cause falls. To avoid injury, wipe up spilled fuel or oil with rags.
To prevent possible injury, wear gloves and protective eye equipment when handling fuel. Failure
to comply may result in injury or death to personnel.
(4)
Install fuel hose (11) on hose connector (12) with clamp (10).